CONTEC Standard Set

CONTEC Standard Set

CONTEC Standard Set

The standard set consists of:
1 x Assortment box, empty
1 x Measuring template

Drills
1 x pilot drill REF 42010
1 x pilot drill REF 43000
1 x calibration drill REF 4400D11
1 x calibration drill REF 44001
1 x calibration drill REF 44002
1 x calibration drill REF 44003
1 x calibration drill REF 44004  

Posts
3 posts from REF 4460D11
5 posts from REF 44601
5 posts from REF 44602
5 posts from REF 44603
3 posts from REF 44604

RRP178,98 € 178,98 € excl. VAT

REF 44600

Product contains 1 Pieces per PU

"Not logged in yet? Log in or sign up for free to access all features!"

To registration / login

Product description

CONTEC is suitable for roots that are rather conical. The double cone approximates the natural shape of the root canal.

HAHNENKRATT was the first company in Germany to offer a carbonfiber root post back in 1995. This was followed in 1998 by the first root post made of quartz fiber. At IDS 2001, we introduced the new CYTEC root post system, made with HT-carbonfiber or HT-Glass Fiber root posts.

As the demand for carbonfiber root posts has decreased considerably in recent years for aesthetic reasons, we no longer offer the CYTEC & CONTEC as carbonfiber posts but only as glass fiber posts. The white, semi-translucent root posts made of HT-Glass Fiber provide you with the basis for esthetically successful restorations.

Explore the details

Advantages of our HT-Glass Fiber root post systems
  • Optimized Flexural Strength

    HT-Glass Fiber, translucent: 1.430 MPa (nach EN ISO 178)
    HT-Glass Fiber, opaque: 1.400 MPa (nach EN ISO 178)

  • Optimized Fatigue and Fracture Resistance
  • Homogeneity through Dentin-like Modulus of Elasticity
  • Optimized, strong bond to composite
  • High radiopacity
Strong adhesive bond thanks to a microporous, micro-retentive post surface

The surface of our root canal posts is retentive. Under SEM, the micro-retentive structure of the glassfiber can be seen, enabling a strong adhesive bond with the composite—without the use of a silane—simple and efficient.

Results from a scientific study at the University of Rostock confirm this for the CYTEC system.

The results are transferable to CONTEC, as both posts share the same surface structure.

Bond strength values

This scientific study was conducted in collaboration between the »Clinic for Dental Prosthetics« and the »Institute of Biomedical Engineering« at the University of Rostock.
The study investigated »The influence of macro- and microstructure on the wetting and retention properties of root canal posts in vitro«.


CYTEC achieved the highest bond strength in comparison. This demonstrates that the unique surface structure of the root posts supports micro-retentive adhesion and leads to optimized bonding between the post and the adhesive cement.


Published in Biomed Tech 2009
Scientific Study at the Universtiy of Rostock*)


*) Felix Worm, Claudia Lurtz, Detlef Behrend, Lena Schmitt,
Klaus-Peter Schmitz, Peter Ottl und Heinrich von Schwanewede
Der Einfluss der Makro- und Mikrostruktur auf die Benetzungs- und Retentionseigenschaften von Wurzelkanalstiften in vitro
Wissenschaftliche Arbeit an der Universität Rostock – Biomed Tech 2009

Downloads

Download our comprehensive resources now and receive valuable information, product catalogs, and more for your practice.

83.01 CONTEC HT Glasfiber
Format: pdf
Size: 722 KB
Version: 2025-12
eIFU & Processing EXATEC, CYTEC & CONTEC
Format: pdf
Size: 1.4 MB
Version: 2024-10 Index 04

Related Products

Root Post Systems
REF 4460XC5
CONTEC posts (refill) from 38,64 € excl. VAT Product contains 5 Pieces per PU
Root Post Systems
REF 4460X
CONTEC posts (refill) from 75,76 € excl. VAT Product contains 10 Pieces per PU

FAQ - Products

In this section, you will find answers to frequently asked questions about our dental instruments, as well as information on the materials, manufacturing, properties, and applications of our products.

Titanium root posts: High rigidity, but higher risk of root fractures
HT glass fiber root posts: Better force distribution, dentin-like modulus of elasticity to minimize root fractures

1. CYTEC 
• Material: HT glass fiber (High Tenacity)
• Shape: Cylindrical-conical
• Surface: Micro-retentive, no silanization needed
• Application: For roots that are mostly cylindrical
• Available in various diameters (e.g., 1.0 mm to 2.1 mm)

2. CONTEC
• Material: HT glass fiber (High Tenacity)
• Shape: Double cone
• Surface: Micro-retentive
• Application: For roots with a conical shape

3. EXATEC
• Material: HT glass fiber or titanium (EXATEC-Ti & EXATEC-S)
• Shape: Conical in the apical area, some with a post head
• Surface: Micro-retentive (for glass fiber versions)
• Application: Especially suitable for teeth with severely destroyed coronal areas

 

The main difference between FS (Front Surface) and RS (Rear Surface) lies in the position of the reflective coating and the resulting image quality:

1. FS (Front Surface) mouth mirror

  • Reflective coating: The reflective layer is on the front side of the glass
  • Materials: Often coated with rhodium or ULTRA coating for high durability, brightness, and chemical resistance
  • Image quality:
    • Only a single reflection, resulting in an extremely sharp, distortion-free mirror image
    • No double images or “ghost images”
    • Excellent color accuracy and contrast

 

2. RS (Rear Surface) mouth mirror

  • Reflective coating: The reflective layer is on the rear side of the glass
  • Materials: Features a silver coating, protected by a copper/titanium layer for high resistance to disinfection and sterilization
  • Image quality:
    • Two reflections
    • May produce double images (“ghost images”)
    • Bright mirror image, but less precise than FS mirrors

The new pro modules feature the same outstanding qualities as the trusted CONTEC and CYTEC root posts, which have been proven for over 30 years, especially through:

  • Optimized flexural strength
    • HT glass fiber, translucent: 1,430 MPa (according to EN ISO 178)
    • HT glass fiber, opaque: 1,400 MPa (according to EN ISO 178)
  • Optimized resistance to fatigue and fracture
  • Dentin-like modulus of elasticity for restorative homogeneity
  • Optimized, strong bond to composite materials
  • high radiopacity

pro LightTransmitting along the entire apical area of the post enables optimized and at the same time shortened initial curing of the composite, right up to the tip of the root post. In a tightly scheduled workflow, every second counts, providing valuable time savings so the dentist can proceed immediately to the next step without delay.

HAHNENKRATT mouth mirrors are manufactured with high-quality mirror coatings and precision components.

Front surface mirrors (FS) prevent double images and provide a clear, distortion-free view.
Depending on the model, different coating technologies are used to optimize brightness, contrast, and durability.

This results in reliable optical quality for precise work in everyday dental practice.

The abbreviations SS and CS refer to the thread types of mouth mirrors and their compatibility with handles:

SS (Simple Stem)
Used in Europe and other regions

CS (Cone Socket)
Conical thread (Cone Socket).
Especially common in the USA, Canada, South Korea, and Spain.