Amanda Gauß
Amanda Gauß CSO | Medical Product Advisor
Telefonnummer +49 7232 3029-0
E-Mail Adresse a.gauss@hahnenkratt.com

About us

90 years dental excellence – made in germany

Contact persons

Your contact for questions, solutions, and advice

Social commitment

Social commitment that makes a difference — locally and worldwide, for children, families, and people in need.

Career

Welcome to the HAHNENKRATT team.

Job Storys

Insights into the daily work and innovative strength of the HAHNENKRATT team.

CYTECpro eco posts (5-refill)

CYTECpro eco posts (5-refill)

CYTECpro eco posts (5-refill)

CYTECpro eco - without retentions

  • Dentin-like modulus of elasticity for homogeneous restorations
  • High stability
  • Suitable for predominantly cylindrical root canals
  • Easy root canal revision

RRP32,47 € from 32,47 € excl. VAT

REF 4390X

Size:
Product contains 5 Pieces per PU

"Not logged in yet? Log in or sign up for free to access all features!"

To registration / login

Product description

 

The new pro line is a good addition to the EXATEC, CYTEC and CONTEC root posts made of HT Glassfiber, which have been tried and tested worldwide for more than 30 years.

It is characterized by the same outstanding properties, particularly with regard to stability and secure bonding with the composite.

pro LightTransmitting over the entire apical post area for an optimized and at the same time shortened primary curing of the composite, right up to the tip of the root post.

The dentist gains valuable seconds in a tightly timed schedule to be able to carry out the next work step without losing time.

Explore the details

CYTECpro eco without retention lines.

With CYTECpro eco, the particularly careful application of the adhesive system is essential, as CYTECpro eco does not have the mesh-like retentions.

Advantages of our HT-Glass Fiber root post systems

The new pro modules feature the same outstanding properties as the proven CONTEC and CYTEC root posts, which have been successfully used for more than 30 years, in particular:

  • Optimized Flexural Strength

    HT-Glass Fiber, translucent: 1.730 MPa (nach EN ISO 178)
    HT-Glass Fiber, opaque: 1.700 MPa (nach EN ISO 178)

  • Optimized Fatigue and Fracture Resistance
  • Homogeneity through Dentin-like Modulus of Elasticity
  • High radiopacity

Downloads

Download our comprehensive resources now and receive valuable information, product catalogs, and more for your practice.

82.02 CYTECpro
Format: pdf
Size: 1.3 MB
Version: 2025-12
eIFU & Processing EXATEC, CYTEC & CONTEC
Format: pdf
Size: 1.4 MB
Version: 2024-10 Index 04

Related Products

Root Post Systems
REF 43900
CYTECpro eco Standard Set 195,00 € excl. VAT Product contains 1 Pieces per PU
Root Post Systems
REF 4380X
CYTECpro posts (10-refill) from 79,75 € excl. VAT Product contains 10 Pieces per PU
Root Post Systems
REF 4360X
CYTEC posts (refill) from 75,76 € excl. VAT Product contains 10 Pieces per PU

FAQ - Products

In this section, you will find answers to frequently asked questions about our dental instruments, as well as information on the materials, manufacturing, properties, and applications of our products.

Titanium root posts: High rigidity, but higher risk of root fractures
HT glass fiber root posts: Better force distribution, dentin-like modulus of elasticity to minimize root fractures

1. CYTEC 
• Material: HT glass fiber (High Tenacity)
• Shape: Cylindrical-conical
• Surface: Micro-retentive, no silanization needed
• Application: For roots that are mostly cylindrical
• Available in various diameters (e.g., 1.0 mm to 2.1 mm)

2. CONTEC
• Material: HT glass fiber (High Tenacity)
• Shape: Double cone
• Surface: Micro-retentive
• Application: For roots with a conical shape

3. EXATEC
• Material: HT glass fiber or titanium (EXATEC-Ti & EXATEC-S)
• Shape: Conical in the apical area, some with a post head
• Surface: Micro-retentive (for glass fiber versions)
• Application: Especially suitable for teeth with severely destroyed coronal areas

 

The main difference between FS (Front Surface) and RS (Rear Surface) lies in the position of the reflective coating and the resulting image quality:

1. FS (Front Surface) mouth mirror

  • Reflective coating: The reflective layer is on the front side of the glass
  • Materials: Often coated with rhodium or ULTRA coating for high durability, brightness, and chemical resistance
  • Image quality:
    • Only a single reflection, resulting in an extremely sharp, distortion-free mirror image
    • No double images or “ghost images”
    • Excellent color accuracy and contrast

 

2. RS (Rear Surface) mouth mirror

  • Reflective coating: The reflective layer is on the rear side of the glass
  • Materials: Features a silver coating, protected by a copper/titanium layer for high resistance to disinfection and sterilization
  • Image quality:
    • Two reflections
    • May produce double images (“ghost images”)
    • Bright mirror image, but less precise than FS mirrors

The new pro modules feature the same outstanding qualities as the trusted CONTEC and CYTEC root posts, which have been proven for over 30 years, especially through:

  • Optimized flexural strength
    • HT glass fiber, translucent: 1,430 MPa (according to EN ISO 178)
    • HT glass fiber, opaque: 1,400 MPa (according to EN ISO 178)
  • Optimized resistance to fatigue and fracture
  • Dentin-like modulus of elasticity for restorative homogeneity
  • Optimized, strong bond to composite materials
  • high radiopacity

pro LightTransmitting along the entire apical area of the post enables optimized and at the same time shortened initial curing of the composite, right up to the tip of the root post. In a tightly scheduled workflow, every second counts, providing valuable time savings so the dentist can proceed immediately to the next step without delay.

HAHNENKRATT mouth mirrors are manufactured with high-quality mirror coatings and precision components.

Front surface mirrors (FS) prevent double images and provide a clear, distortion-free view.
Depending on the model, different coating technologies are used to optimize brightness, contrast, and durability.

This results in reliable optical quality for precise work in everyday dental practice.

The abbreviations SS and CS refer to the thread types of mouth mirrors and their compatibility with handles:

SS (Simple Stem)
Used in Europe and other regions

CS (Cone Socket)
Conical thread (Cone Socket).
Especially common in the USA, Canada, South Korea, and Spain.

Do you have any questions or would you like product advice?

Mrs. Gauß, our medical product advisor, will be happy to assist you.

AG HAHNENKRATT NOV04

Amanda Gauß

CSO | Medical Product Advisor