PCP22

PCP22

BLACK PSI periodontometer with DLC coating (diamond-like carbon)

Scaling 2 - 4 - 6 - 8 - 10 - 12 mm

available with or without a handle

RRP11,34 € from 11,34 € excl. VAT

REF

Handle:
without handle 442 B442 5012 546
Product contains 1 Pieces per PU

"Not logged in yet? Log in or sign up for free to access all features!"

To registration / login

Product description

Our BLACK periodontometers are made of stainless medical steel and a deep-black Diamond-like Carbon DLC) coating. This makes the instrument particularly durable. The explorer and handle are permanently fixed and cannot be unscrewed.    

Explore the details

Advantages of the BLACKline PSI periodontometer:
  • Deep black DLC – Diamond-Like Carbon coating for maximum contrast and optimized readability
  • The wear-free, non-fading scaling ensures very good recognition of the measurement results
  • Seamless transitions in the measuring range

Downloads

Download our comprehensive resources now and receive valuable information, product catalogs, and more for your practice.

10.01 PSI Periodontometer
Format:
Size:
EN ISO 17664-1 Manufacturer information Instruments (mouth mirror, laryngeal mirror, photo mirrors, micro mirrors, handles for mouth mirrors, periodontal probe, explorers)
Format: pdf
Size: 744 KB
Version: 2024-04 Index 04

Related Products

BLACKline
REF B442, B443
BLACK ERGOtouch handle stainless steel + DLC from 14,28 € excl. VAT Product contains 1 Pieces per PU
PCP12 from 11,34 € excl. VAT Product contains 1 Pieces per PU
PCP11 from 11,34 € excl. VAT Product contains 1 Pieces per PU

FAQ - Products

In this section, you will find answers to frequently asked questions about our dental instruments, as well as information on the materials, manufacturing, properties, and applications of our products.

Titanium root posts: High rigidity, but higher risk of root fractures
HT glass fiber root posts: Better force distribution, dentin-like modulus of elasticity to minimize root fractures

1. CYTEC 
• Material: HT glass fiber (High Tenacity)
• Shape: Cylindrical-conical
• Surface: Micro-retentive, no silanization needed
• Application: For roots that are mostly cylindrical
• Available in various diameters (e.g., 1.0 mm to 2.1 mm)

2. CONTEC
• Material: HT glass fiber (High Tenacity)
• Shape: Double cone
• Surface: Micro-retentive
• Application: For roots with a conical shape

3. EXATEC
• Material: HT glass fiber or titanium (EXATEC-Ti & EXATEC-S)
• Shape: Conical in the apical area, some with a post head
• Surface: Micro-retentive (for glass fiber versions)
• Application: Especially suitable for teeth with severely destroyed coronal areas

 

The main difference between FS (Front Surface) and RS (Rear Surface) lies in the position of the reflective coating and the resulting image quality:

1. FS (Front Surface) mouth mirror

  • Reflective coating: The reflective layer is on the front side of the glass
  • Materials: Often coated with rhodium or ULTRA coating for high durability, brightness, and chemical resistance
  • Image quality:
    • Only a single reflection, resulting in an extremely sharp, distortion-free mirror image
    • No double images or “ghost images”
    • Excellent color accuracy and contrast

 

2. RS (Rear Surface) mouth mirror

  • Reflective coating: The reflective layer is on the rear side of the glass
  • Materials: Features a silver coating, protected by a copper/titanium layer for high resistance to disinfection and sterilization
  • Image quality:
    • Two reflections
    • May produce double images (“ghost images”)
    • Bright mirror image, but less precise than FS mirrors

The new pro modules feature the same outstanding qualities as the trusted CONTEC and CYTEC root posts, which have been proven for over 30 years, especially through:

  • Optimized flexural strength
    • HT glass fiber, translucent: 1,430 MPa (according to EN ISO 178)
    • HT glass fiber, opaque: 1,400 MPa (according to EN ISO 178)
  • Optimized resistance to fatigue and fracture
  • Dentin-like modulus of elasticity for restorative homogeneity
  • Optimized, strong bond to composite materials
  • high radiopacity

pro LightTransmitting along the entire apical area of the post enables optimized and at the same time shortened initial curing of the composite, right up to the tip of the root post. In a tightly scheduled workflow, every second counts, providing valuable time savings so the dentist can proceed immediately to the next step without delay.

HAHNENKRATT mouth mirrors are manufactured with high-quality mirror coatings and precision components.

Front surface mirrors (FS) prevent double images and provide a clear, distortion-free view.
Depending on the model, different coating technologies are used to optimize brightness, contrast, and durability.

This results in reliable optical quality for precise work in everyday dental practice.

The abbreviations SS and CS refer to the thread types of mouth mirrors and their compatibility with handles:

SS (Simple Stem)
Used in Europe and other regions

CS (Cone Socket)
Conical thread (Cone Socket).
Especially common in the USA, Canada, South Korea, and Spain.